Electrochemical Detector nrog DC, PULSE thiab SCAN hom

Lus piav qhia luv luv:

Nyob rau hauv cov ntaub ntawv ntawm cov ntaub ntawv voltage, lub electrochemical detector pom qhov kev hloov ntawm tam sim no los ntawm redox cov tshuaj tiv thaiv ntawm cov tshuaj yuav tsum tau ntsuas nyob rau hauv lub electrode nto.Electrochemical detector feem ntau yog siv los soj ntsuam ions nrog tsawg dissociation, uas yog ib qho nyuaj rau kev ntes nrog conductivity detectors thiab muaj hluav taws xob ua.
Technology Advantage

Tshwj xeeb suab nrov txo technology

Advanced Digital Filter (ADF), txawv ntawm ib txwm lim lub sij hawm tas li (FTC), muaj cov teeb liab tsawg dua hauv cov txheej txheem ntawm kev txo suab nrov, uas tuaj yeem ua rau qis qis qis dua, tshem tawm cov suab nrov nrov, txhim kho cov teeb liab-rau-suab nrov piv thiab nce. kuaj pom qhov txwv.
Cov qauv tshwj xeeb ntawm analytical flow cell
Central tsuag phab ntsa qauv.Lub rhiab heev ntawm analytical flow cell tuaj yeem hloov kho tas li.Lub ntim ua haujlwm tuaj yeem hloov kho tsis tu ncua ntawm 0 thiab 300 nl.One electrode tuaj yeem ua tau raws li daim ntawv thov ntawm qhov sib txawv rhiab heev.
Built-in Faraday shielded kub qhov cub
Txo cov kev cuam tshuam zoo li qub thiab tsis piav qhia thiab cuam tshuam ntawm kev hloov pauv kub, txhim kho rov ua dua thiab ruaj khov.
Muaj feem xyuam rau IC, HPLC thiab UHPLC
Nrog DC, PULSE thiab SCAN hom
Qhov tseem ceeb tshaj plaws electrochemical detector
Sib txawv ntws cov hlwb los npog txhua daim ntawv thov


Product Detail

Khoom cim npe

Qhov tseem ceeb

Hom DC, PULSE thiab SCAN
Ua haujlwm kub 10-40 ℃ (tsuas yog siv sab hauv tsev)
Kev nyab xeeb thiab EMC Raws li Ec-cov lus qhia;Emission Group I Class A; cMETus pom zoo
Sensors Txog li 3 lub hlwb khiav
Max tam sim no them nyiaj (Autozero) - 25 nA-25 mA hauv DC thiab PULSE hom nyob ntawm qhov chaw teeb tsa
Qhov cub +7 ° C saum ambient mus rau 60 ° C, qhov tseeb 0.5 ° C, ruaj khov 0.1 ° C;haum rau kab thiab ntws cell(s)
Offset 50% - 50% ntawm max.tso zis voltage, 5% kauj ruam
Analog tso zis (DAC) -1 rau +1 V tag nrho teev (ntawm 16-ntsis D / A converter)
Analog tso zis (I / E) -2.5 txog +2.5V tag nrho teev (tsis ua tiav I / E con-verter teeb liab)
DC hom
Ntau yam 10 pA-200 uA hauv 1. 2. 5 increments
Filter (ADF) 10-0.001 Hz hauv 1.2.5 nce

RAW thiab OFF: rau cov ntaub ntawv tsis tau ua tiav

Muaj peev xwm (EC) -2.50V rau +2.50V nrog 10 mV increments
Cov ntaub ntawv tus nqi 1-100 Hz hauv 1, 2, 5 increments, nyob ntawm qhov chaw lim
Suab nrov <2pA nrog dummy cell (load ntawm 300 MΩ / 470 pF) hauv 1 nA ntau yam, lim tawm, Ec + 800mV thiab kub ntawm 35'C
PULSE hom
Ntau yam 10 nA - 200 μA hauv 1, 2, 5 increments

OFF: rau cov ntaub ntawv tsis tau ua tiav

Filter (ADF) 0.5 - 0.001 Hz hauv 1, 2, 5 increments
Muaj peev xwm (Ec) -2.50 V rau + 2.50 V nrog 10 mV increments
Cov ntaub ntawv tus nqi 1 / (mem tes ntev) Hz
SCAN hom
Ntau yam 10 nA - 200 μA hauv 1, 2, 5 increments
Muaj peev xwm (Ec) -2.50 V rau + 2.50V nrog 10 mV increments
Cov ntaub ntawv tus nqi 1 Hz Scan tus nqi 1 - 100 mV / s hauv 1, 2, 5 increments
Lwm tus
Lub voj voog Ib nrab, Tag Nrho, Nruam
Qhov ntev 43 (D) * 22 (W) * 44 (H) cm
Lub zog xav tau 100-240 VAC, 50/60 Hz, 260 VA, nws pib-sensing
Qhov hnyav Max 14. 4 kg tsis ntws ntawm tes thiab kab

  • Yav dhau los:
  • Tom ntej:

  • Cov khoom qeb